Product

Household Combustible Gas Detector JM-RTCO15-Z1

Carbon-containing substances such as coal, petroleum, and wood will produce carbon monoxide when burned in an oxygen-deficient environment. For example, in the process of household heating equipment, kitchen stoves, industrial coal burning, etc., insufficient combustion will produce carbon monoxide. Carbon monoxide is a toxic gas, and when it exceeds a certain concentration, it will cause serious harm to human health. This product can monitor the concentration of carbon monoxide in the air and alarm in a timely manner when it exceeds the standard to prevent accidents before they occur.
  • Detailed Description

 

Main Product Functions:

  1. Communication Method: Tuya ZigBee
  2. Clear Working Indication Function: It has signal strength indication, signal transmission indication, and indication functions for various operating states of the product.
  3. Powerful Self-Check Function: It has self-check functions such as module fault detection, signal transmission failure detection, and platform communication fault detection.
  4. Flexible Cloud Platform Configuration Function: Various functions of the product can be remotely set through the cloud platform.
  5. Compatible with ceiling-mounted and wall-mounted installation methods.
  6. Equipped with clock function and memory function.
  7. Equipped with data export interface.
  8. 1-channel Relay Output
  9. Equipped with the test report from the National Fire Electronic Product Quality Inspection and Testing Center.
  10. Equipped with the fire product certification certificate from the Fire Product Certification Center of the Ministry of Emergency Management.

 

Product Technical Parameters:

  • Communication Method: Tuya ZigBee
  • Detected Gas: Carbon Monoxide (CO)
  • Alarm Concentration: 200×10⁻⁶(volume fraction)
  • Measurement Range: 0-500×10⁻⁶(volume fraction)
  • Operating Temperature: -10~+55℃
  • Installation Method: Ceiling-mounted / Wall-mounted
  • Overall Dimensions: Φ104×7mm
  • Power Consumption: ≤2W in normal monitoring state; ≤3W in alarm state
  • Operating Voltage: AC 220V/50Hz
  • Alarm Volume: >70dB (1 meter in front)
  • Sampling Method: Natural Diffusion
  • Operating Humidity: ≤95%RH
  • Driving Capacity: AC 220V/3A or DC 30V/3A (relay normally open output mode)
  • Sensor Lifespan: 3 years

 

Copyright © 2025 rainontrees